Spectrophotometric determination of total nitrogen in plant materials using a flow-injection system with an Ag'Cl IND.s' reactor (2000)
- Authors:
- Autor USP: ZAGATTO, ELIAS AYRES GUIDETTI - CENA
- Unidade: CENA
- DOI: 10.1016/s0003-2670(00)00898-9
- Subjects: QUÍMICA ANALÍTICA; QUÍMICA ANALÍTICA INSTRUMENTAL
- Language: Inglês
- Abstract: An improved flow-injection system with an AgCl(s) reactor is proposed for the spectrophotometric determination of total nitrogen in Kjedahl digest of plant materials. After sample injection, the established sample plug is alkalinized and allowedto flow through the mini-column where Ag+ ions are displaced as the soluble [Ag(NH3)s]+ complex. Bromopyrogallol red and 0-phenanthroline are then added and a coloured ternary complex is formed under neutral conditions. The system is verystable, and baseline drift is usually <0.01 absorbance after 4 h operation periods. Precise results (R.S.D.<2%) are obtained at a rate of 100h-1. The analytical curve is linear up to 6.00% (w/w) N (dry basis), regression coefficient has beenestimated as >0.999 (n=6) and detection limit is 0.2% (w/w) N. Accuracy was confirmed by running standard reference materials and typical samples already assayed by conductimetry
- Imprenta:
- Source:
- Título do periódico: Analytica Chimica Acta
- Volume/Número/Paginação/Ano: v.416, n.2, p.185-190, 2000
- Este periódico é de assinatura
- Este artigo NÃO é de acesso aberto
- Cor do Acesso Aberto: closed
-
ABNT
CARNEIRO, J M T e SARTINI, R P e ZAGATTO, Elias Ayres Guidetti. Spectrophotometric determination of total nitrogen in plant materials using a flow-injection system with an Ag'Cl IND.s' reactor. Analytica Chimica Acta, v. 416, n. 2, p. 185-190, 2000Tradução . . Disponível em: https://doi.org/10.1016/s0003-2670(00)00898-9. Acesso em: 27 abr. 2024. -
APA
Carneiro, J. M. T., Sartini, R. P., & Zagatto, E. A. G. (2000). Spectrophotometric determination of total nitrogen in plant materials using a flow-injection system with an Ag'Cl IND.s' reactor. Analytica Chimica Acta, 416( 2), 185-190. doi:10.1016/s0003-2670(00)00898-9 -
NLM
Carneiro JMT, Sartini RP, Zagatto EAG. Spectrophotometric determination of total nitrogen in plant materials using a flow-injection system with an Ag'Cl IND.s' reactor [Internet]. Analytica Chimica Acta. 2000 ;416( 2): 185-190.[citado 2024 abr. 27 ] Available from: https://doi.org/10.1016/s0003-2670(00)00898-9 -
Vancouver
Carneiro JMT, Sartini RP, Zagatto EAG. Spectrophotometric determination of total nitrogen in plant materials using a flow-injection system with an Ag'Cl IND.s' reactor [Internet]. Analytica Chimica Acta. 2000 ;416( 2): 185-190.[citado 2024 abr. 27 ] Available from: https://doi.org/10.1016/s0003-2670(00)00898-9 - Exploitation of a single interface flow system for on-line aqueous biphasic extraction: a Brazilian triumph. [Entrevista a Adimilson Cerqueira]
- Determinação espectrofotométrica simultânea de cobre e níquel explorando cinética diferencial e quimiometria
- Mini-sondas em sistemas de análise em fluxo:: uma estratégia pouco invasiva
- Multipumping flow systems: an alternative approach to sample handling in spectroscopy measurements
- Determinacao de cromo e niquel em ligas metalicas empregando sistemas de injecao em fluxo com coalescencia parcial e espectrometria de absorcao atomica
- Relocalizacao de detectores em sistemas fia: determinacao de glicerol empregando eletrodo seletivo a periodato
- Sistema automatizado para classificacao de amostras de alimentos baseada em teores de chumbo e cadmio
- Emprego de resina cationica para remocao de ferro visando a determinacao catalitica de vanadio em materiais vegetais
- Compensacao do efeito schilieren na eluicao sequencial de metais cloro-complexados visando analises multi-parametricas de alimentos
- An automated titrator based on a flow-batch hybrid system exploiting the Fibonacci method
Informações sobre o DOI: 10.1016/s0003-2670(00)00898-9 (Fonte: oaDOI API)
How to cite
A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas