Mechanical properties of polypropylene mesh used in pelvic floor repair (2008)

  • Authors:
  • USP affiliated authors: BARACAT, EDMUND CHADA - FM
  • USP Schools: FM
  • DOI: 10.1007/s00192-007-0446-1
  • Subjects: UROLOGIA; GINECOLOGIA; PROCEDIMENTOS CIRÚRGICOS RECONSTRUTIVOS
  • Language: Inglês
  • Imprenta:
  • Source:
  • Acesso online ao documento

    Online accessDOI or search this record in
    Informações sobre o DOI: 10.1007/s00192-007-0446-1 (Fonte: oaDOI API)
    • Este periódico é de assinatura
    • Este artigo NÃO é de acesso aberto
    • Cor do Acesso Aberto: closed
    Informações sobre o Citescore
  • Título: International Urogynecology Journal and Pelvic Floor Dysfunction

    ISSN: 0937-3462

    Citescore - 2017: 1.67

    SJR - 2017: 0.932

    SNIP - 2017: 1.129


  • Exemplares físicos disponíveis nas Bibliotecas da USP
    BibliotecaCód. de barrasNúm. de chamada
    FM10700092505-SFM BCSEP 095 2008
    How to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas

    • ABNT

      AFONSO, J. S.; MARTINS, P. A. L. S.; GIRÃO, M. J. B. C.; et al. Mechanical properties of polypropylene mesh used in pelvic floor repair. International Urogynecology Journal, Surrey, v. 19, n. 3, p. 375-380, 2008. Disponível em: < http://www.springerlink.com/content/f523v2720517l783/fulltext.pdf > DOI: 10.1007/s00192-007-0446-1.
    • APA

      Afonso, J. S., Martins, P. A. L. S., Girão, M. J. B. C., Jorge, R. M. N., Ferreira, A. J. M., Mascarenhas, T., et al. (2008). Mechanical properties of polypropylene mesh used in pelvic floor repair. International Urogynecology Journal, 19( 3), 375-380. doi:10.1007/s00192-007-0446-1
    • NLM

      Afonso JS, Martins PALS, Girão MJBC, Jorge RMN, Ferreira AJM, Mascarenhas T, Fernandes AA, Bernardes J, Baracat EC, Lima GR de, Patricio B. Mechanical properties of polypropylene mesh used in pelvic floor repair [Internet]. International Urogynecology Journal. 2008 ; 19( 3): 375-380.Available from: http://www.springerlink.com/content/f523v2720517l783/fulltext.pdf
    • Vancouver

      Afonso JS, Martins PALS, Girão MJBC, Jorge RMN, Ferreira AJM, Mascarenhas T, Fernandes AA, Bernardes J, Baracat EC, Lima GR de, Patricio B. Mechanical properties of polypropylene mesh used in pelvic floor repair [Internet]. International Urogynecology Journal. 2008 ; 19( 3): 375-380.Available from: http://www.springerlink.com/content/f523v2720517l783/fulltext.pdf

    Referências citadas na obra
    Wriggers P (2006) Computational contact mechanics, 2nd edn. Springer, New York
    Weaver BT, Haut RC (2005) Enforced exercise after blunt trauma significantly affects biomechanical and histological changes in rabbit retro-patellar cartilage. J Biomech 38:1177–1183
    Deffieux X, Tayrac R, Huel C, Bottero J, Gervaise A, Bonnet K, Frydman R, Fernandez H (2007) Vaginal mesh erosion after transvaginal repair of cystocele using Gynemesh or Gynemesh-Soft in 138 women: a comparative study. Int Urogynecol J 18:73–79
    Petros PE (2007) Repairing damage fascia: ongoing and post operative considerations. In: Petros PE (ed) The female pelvic floor. Springer, Berlin, pp 108–156
    Abdel-Fattah M, Sivanesan K, Ramsay I, Pringle S, Bjornsson S (2006) How common are tape erosions? A comparison of two versions of the transobturator tension-free vaginal tape procedure. BJU Int 98(3):594–598
    Siegel AL (2005) Vaginal mesh extrusion associated with use of Mentor transobturator sling. Urology 66:995–999
    Siegel AL, Kim M, Goldstein M, Levey S, Ilbeigi P (2005) High incidence of vaginal mesh extrusion using the intravaginal slingplasty sling. Urol J 174:1308–1311
    Falconer C, Söderberg M, Blomgren B, Ulmsten U (2001) Influence of different sling materials on connective tissue metabolism in stress urinary incontinent women. Int Urogynecol J Suppl 2:S19–S23
    Cosson M, Debodinance P, Boukerrou M, Chauvet MP, Pierre L, Crépin G, Ego A (2003) Mechanical properties of synthetic repair of prolapse and urinary incontinence which is the ideal material. Int Urogynecol J 14:169–178
    Comiter CV, Colegrove PM (2004) High. rate of vaginal extrusion of silicone-coated polyester sling. Urology 63:1066–1070
    Johnson & Johnson (2003) Nonabsorbable prolene soft mesh. Gynecare Gynemesh PS, p 2
    Martins PALS, Jorge RMN, Ferreira AJM (2006) A comparative study of several material models for prediction of hyperelastic properties: application to silicone-rubber and soft tissues. Strain 42:135–147
    Dietz H, Vancaillie P, Svehla M, Walsh W, Steensma A, Vancaillie T (2003) Mechanical properties of urogynecologic implant materials. Int Urogynecol J 14:239–243
    Schumpelick V, Klinge U, Welty G, Klosterhalfen B (1999) Meshes within the abdominal wall (in German). Chirurgie 70:876–887
    Fung YC (1993) Biomechanics: mechanical properties of living tissues, 2nd edn. Springer, Berlin, p 261
    Moser AP (2001) Buried pipe design, 2nd edn. McGraw-Hill, New York, p 267
    Fenner DE (2000) New surgical mesh. Clin Obstet Gynecol 43:650–658
    Feifer A, Corcos J (2007) The use of synthetic sub-urethral slings in the treatment of female stress urinary incontinence. Int Urogynecol J 18:1087–1095
    Neymeyer J, Abdul-Wahab W, Beer M, Spethmann J, Groneberg D, Große-Siestrup C (2007) Laboratory Testing of suburethral mesh slings: A comparison of their static and dynamic properties. Int Urogynecol J 18(Suppl 1):S111
    Popov EP (1990) Engineering Mechanics of Solids. PRENTICE-HALL, chap. 6 Gynemesh or Gynemesh-Soft in 138 women: a comparative study. Int Urogynecol J 18:73–79
    Deval B, Ferchaux J, Berry R, Gambino S, Ciofu C, Rafii A, Haab F (2006) Objective and subjective cure rates after trans-obturator tape (OBTAPE) treatment of female urinary incontinence. Eur Urol 49:373–377 (in Int Braz J Urol 33(1):101–124, January–February 2007)