Ver registro no DEDALUS
Exportar registro bibliográfico

Metrics


Metrics:

In vitro analysis of the influence of surface treatment of dental implants on primary stability (2012)

  • Authors:
  • USP affiliated authors: REIS, ANDRÉA CANDIDO DOS - FORP ; SHIMANO, ANTONIO CARLOS - FMRP
  • USP Schools: FORP; FMRP
  • DOI: 10.1590/s1806-83242012005000006
  • Subjects: IMPLANTES DENTÁRIOS; ÓSSEOINTEGRAÇÃO; RESISTÊNCIA A TRAÇÃO; TRATAMENTO DE SUPERFÍCIES
  • Language: Inglês
  • Abstract: Surface treatment interferes with the primary stability of dental implants because it promotes a chemical and micromorphological change on the surface and thus stimulates osseointegration. This study aimed to evaluate the effects of different surface treatments on primary stability by analyzing insertion torque (IT) and pullout force (PF). Eight samples of implants with different surface treatments (TS - external hexagon with acid surface treatment; and MS - external hexagon, machined surface), all 3.75 mm in diameter X 11.5 mm in length, were inserted into segments of artificial bones. The IT of each sample was measured by an electronic torquemeter, and then the pullout test was done with a universal testing machine. The results were subjected to ANOVA (p < 0.05), followed by Tukey's test (p < 0.05). The IT results showed no statistically significant difference, since the sizes of the implants used were very similar, and the bone used was not highly resistant. The PF values (N) were, respectively, TS = 403.75 ± 189.80 and MS = 276.38 ± 110.05. The implants were shown to be different in terms of the variables of maximum force (F = 4.401, p = 0.0120), elasticity in maximum flexion (F = 3.672, p = 0.024), and relative stiffness (F = 4.60, p = 0.01). In this study, external hexagonal implants with acid surface treatment showed the highest values of pullout strength and better stability, which provide greater indication for their use
  • Imprenta:
  • Source:
  • Acesso online ao documento

    Online accessDOI or search this record in
    Informações sobre o DOI: 10.1590/s1806-83242012005000006 (Fonte: oaDOI API)
    • Este periódico é de acesso aberto
    • Este artigo é de acesso aberto
    • URL de acesso aberto
    • Cor do Acesso Aberto: hybrid
    • Licença: cc-by-nc

    Exemplares físicos disponíveis nas Bibliotecas da USP
    BibliotecaCód. de barrasNúm. de chamada
    FMRP2319162pcd 2319162 Estantes Deslizantes
    How to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas

    • ABNT

      MAZZO, Carla Rodrigues; REIS, Andréa Cândido dos; SHIMANO, Antonio Carlos; VALENTE, Mariana Lima da Costa. In vitro analysis of the influence of surface treatment of dental implants on primary stability. Brazilian Oral Research, São Paulo, v. 26, n. 4, p. 313-317, 2012. Disponível em: < http://dx.doi.org/10.1590/S1806-83242012005000006 > DOI: 10.1590/s1806-83242012005000006.
    • APA

      Mazzo, C. R., Reis, A. C. dos, Shimano, A. C., & Valente, M. L. da C. (2012). In vitro analysis of the influence of surface treatment of dental implants on primary stability. Brazilian Oral Research, 26( 4), 313-317. doi:10.1590/s1806-83242012005000006
    • NLM

      Mazzo CR, Reis AC dos, Shimano AC, Valente ML da C. In vitro analysis of the influence of surface treatment of dental implants on primary stability [Internet]. Brazilian Oral Research. 2012 ; 26( 4): 313-317.Available from: http://dx.doi.org/10.1590/S1806-83242012005000006
    • Vancouver

      Mazzo CR, Reis AC dos, Shimano AC, Valente ML da C. In vitro analysis of the influence of surface treatment of dental implants on primary stability [Internet]. Brazilian Oral Research. 2012 ; 26( 4): 313-317.Available from: http://dx.doi.org/10.1590/S1806-83242012005000006

    Referências citadas na obra
    Autor: Hagberg K
    Título: One hundred patients treated with osseointegrated transfemoral amputation prostheses: rehabilitation perspective
    Título do periódico: J Rehabil Res Dev
    Volume: 46
    Fascículo: 3
    Primeira página: 331
    Ano: 2009
    DOI: 10.1682/JRRD.2008.06.0080
    Autor: Brentel AS
    Título: Histomorphometric analysis of pure titanium implants with porus surface versus rough surface
    Título do periódico: J Appl Oral Sci
    Volume: 14
    Fascículo: 3
    Primeira página: 213
    Ano: 2006
    DOI: 10.1590/S1678-77572006000300013
    Autor: Castilho GAA
    Título: Surface characterization of titanium based dental implants
    Título do periódico: Braz J Phys
    Volume: 36
    Fascículo: 3
    Primeira página: 1004
    Ano: 2006
    DOI: 10.1590/S0103-97332006000600055
    Autor: Gahlert M
    Título: Osseointegration of zirconia and titanium dental implants: a histological and histomorphometrical study in the maxilla of pigs
    Título do periódico: Clin Oral Implants Res
    Volume: 20
    Fascículo: 11
    Primeira página: 1247
    Ano: 2009
    DOI: 10.1111/j.1600-0501.2009.01734.x
    Autor: Gebran MP
    Título: Evaluation in vitro of the adhesion of osteoblasts on osseointegrated implant with treated surface (Titamax IIÒ)
    Título do periódico: Implant News
    Volume: 4
    Fascículo: 1
    Primeira página: 79
    Ano: 2007
    Autor: Fathi MH
    Título: Novel hydroxiapatite/tantalum surface coating for metallic dental implant
    Título do periódico: Mater Lett
    Volume: 61
    Fascículo: 4-5
    Primeira página: 1238
    Ano: 2007
    DOI: 10.1016/j.matlet.2006.07.013
    Autor: Citeau A
    Título: In vitro biological effects of titanium rough surface obtained by calcium phosphate grid blasting
    Título do periódico: Biomaterials
    Volume: 26
    Fascículo: 2
    Primeira página: 157
    Ano: 2005
    DOI: 10.1016/j.biomaterials.2004.02.033
    Autor: De Maetzu MA
    Título: Improvement of osseointegration of titanium dental implant surfaces modified with CO ions: a comparative histomorphometric study in beagle dogs
    Título do periódico: Int J Oral Maxillofac Surg
    Volume: 37
    Fascículo: 5
    Primeira página: 441
    Ano: 2008
    DOI: 10.1016/j.ijom.2008.01.010
    Autor: Le Guéhennec L
    Título: Surface treatments of titanium dental implants for rapid osseointegration
    Título do periódico: Dent Mater
    Volume: 23
    Fascículo: 7
    Primeira página: 844
    Ano: 2007
    DOI: 10.1016/j.dental.2006.06.025
    Autor: Li DH
    Título: Improvement of osseointegration of titanium dental implants by a modified sandblasting surface treatment: an in vivo interfacial biomechanics study
    Título do periódico: Implant Dent
    Volume: 8
    Fascículo: 3
    Primeira página: 289
    Ano: 1999
    DOI: 10.1097/00008505-199903000-00014
    Autor: Sollazzo V
    Título: Zirconium oxide coating improves implant osseointegration in vivo
    Título do periódico: Dent Mater
    Volume: 24
    Fascículo: 3
    Primeira página: 357
    Ano: 2008
    DOI: 10.1016/j.dental.2007.06.003
    Autor: Akça K
    Título: Biomechanical aspects of initial intraosseous stability and implant design: a quantitative micromorphometric analysis
    Título do periódico: Clin Oral Implants Res
    Volume: 17
    Fascículo: 4
    Primeira página: 465
    Ano: 2006
    DOI: 10.1111/j.1600-0501.2006.01265.x
    Autor: Amarante ES
    Título: Optimization of implant surfaces: titanium plasma spray and acid-etched sandblasting-current state
    Título do periódico: Pesqui Odontol Bras
    Volume: 15
    Fascículo: 2
    Primeira página: 166
    Ano: 2002
    Autor: Kahraman S
    Título: Clinical study on the insertion torque and wireless resonance frequency analysis in the assessment of torque capacity and stability of self-tapping dental implants
    Título do periódico: J Oral Rehabil
    Volume: 36
    Fascículo: 10
    Primeira página: 755
    Ano: 2009
    DOI: 10.1111/j.1365-2842.2009.01990.x
    Autor: Defino HL
    Título: The effect of repetitive pilot-hole use on insertion torque and pullout strength of vertebral system screws
    Título do periódico: Spine (Phila Pa 1976)
    Volume: 34
    Fascículo: 9
    Primeira página: 871
    Ano: 2009
    DOI: 10.1097/BRS.0b013e31819e3556
    Autor: Kim JW
    Título: Comparison of stability between cylindrical and conical type mini-implants
    Título do periódico: Angle Orthod
    Volume: 78
    Fascículo: 4
    Primeira página: 692
    Ano: 2008
    DOI: 10.2319/0003-3219(2008)078[0692:COSBCA]2.0.CO;2
    Autor: Turkyilmaz I
    Título: Biomechanical aspects of primary implant stability: a human cadaver study
    Título do periódico: Clin Implant Dent Relat Res
    Volume: 11
    Fascículo: 2
    Primeira página: 113
    Ano: 2009
    DOI: 10.1111/j.1708-8208.2008.00097.x
    Autor: González JMM
    Título: Removal torque and physico-quimical characteristics of dental implants etched with hydrofluoric and nitric acid: An experimental study in beagle dogs
    Título do periódico: Med Oral Patol Oral Cir Bucal
    Volume: 11
    Fascículo: 3
    Primeira página: 281
    Ano: 2006
    Autor: Stüker RA
    Título: Preload and torque removal evaluation of three different abutment screws for single standing implant restorations
    Título do periódico: J Appl Oral Sci
    Volume: 16
    Fascículo: 1
    Primeira página: 55
    Ano: 2008
    DOI: 10.1590/S1678-77572008000100011
    Autor: Cristofolini L
    Título: Mechanical validation of whole bone composite femur models
    Título do periódico: J Biomech
    Volume: 29
    Fascículo: 4
    Primeira página: 525
    Ano: 1996
    DOI: 10.1016/0021-9290(95)00084-4
    Autor: Cristofolini L
    Título: Mechanical validation of whole composite tibia models
    Título do periódico: J Biomech
    Volume: 33
    Fascículo: 3
    Primeira página: 279
    Ano: 2000
    DOI: 10.1016/S0021-9290(99)00186-4
    Autor: Hsu SH
    Título: Characterization and biocompatibility of a titanium dental implant with a laser irradiated and dual-acid etched surface
    Título do periódico: Biomed Mater Eng
    Volume: 17
    Fascículo: 1
    Primeira página: 53
    Ano: 2007
    Autor: Misch CE
    Título: Density of bone: effect on treatment plans, surgical approach, healing, and progressive bone loading
    Título do periódico: Int J Oral Implantol
    Volume: 6
    Fascículo: 2
    Primeira página: 23
    Ano: 1990
    Autor: Lim SA
    Título: Insertion torque of orthodontic miniscrews according to changes in shape, diameter and length
    Título do periódico: Angle Orthod
    Volume: 78
    Fascículo: 2
    Primeira página: 234
    Ano: 2008
    DOI: 10.2319/121206-507.1
    Autor: Langhoff JD
    Título: Comparison of chemically and pharmaceutically modified titanium and zirconia implant surfaces in dentistry: a study in sheep
    Título do periódico: Int J Oral Maxillofac Surg
    Volume: 37
    Fascículo: 12
    Primeira página: 1125
    Ano: 2008
    DOI: 10.1016/j.ijom.2008.09.008
    Autor: Ohta K
    Título: Influence of factors related to implant stability detected by wireless resonance frequency analysis device
    Título do periódico: J Oral Rehabil
    Volume: 37
    Fascículo: 2
    Primeira página: 131
    Ano: 2010
    DOI: 10.1111/j.1365-2842.2009.02032.x