Ver registro no DEDALUS
Exportar registro bibliográfico

Metrics


Metrics:

Experimental in vivo acute and chronic biomechanical and histomorphometrical comparison of self-drilling and self-tapping anterior cervical screws (2012)

  • Authors:
  • USP affiliated authors: DEFINO, HELTON LUIZ APARECIDO - FMRP ; VOLPON, JOSÉ BATISTA - FMRP ; SHIMANO, ANTONIO CARLOS - FMRP ; PAULA, FRANCISCO JOSE ALBUQUERQUE DE - FMRP
  • USP Schools: FMRP; FMRP; FMRP; FMRP
  • DOI: 10.1007/s00586-011-2120-z
  • Subjects: BIOMECÂNICA; DENSIDADE ÓSSEA; VÉRTEBRAS CERVICAIS (PATOLOGIA;CIRURGIA); MODELOS ANIMAIS
  • Language: Inglês
  • Imprenta:
  • Source:
  • Acesso online ao documento

    Online accessDOI or search this record in
    Informações sobre o DOI: 10.1007/s00586-011-2120-z (Fonte: oaDOI API)
    • Este periódico é de assinatura
    • Este artigo é de acesso aberto
    • URL de acesso aberto
    • Cor do Acesso Aberto: green
    Informações sobre o Citescore
  • Título: European Spine Journal

    ISSN: 0940-6719

    Citescore - 2017: 2.35

    SJR - 2017: 1.535

    SNIP - 2017: 1.419


  • Exemplares físicos disponíveis nas Bibliotecas da USP
    BibliotecaCód. de barrasNúm. de chamada
    FMRP2319528pcd 2319528 Estantes Deslizantes
    How to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas

    • ABNT

      PORTO, Maximiliano Aguiar; SILVA, Patrícia; ROSA, Rodrigo; et al. Experimental in vivo acute and chronic biomechanical and histomorphometrical comparison of self-drilling and self-tapping anterior cervical screws. European Spine Journal, Heidelberg, v. 21, n. 5, p. 956-963, 2012. Disponível em: < http://dx.doi.org/10.1007/s00586-011-2120-z > DOI: 10.1007/s00586-011-2120-z.
    • APA

      Porto, M. A., Silva, P., Rosa, R., Volpon, J. B., Shimano, A. C., Paula, F. J. A. de, & Defino, H. L. A. (2012). Experimental in vivo acute and chronic biomechanical and histomorphometrical comparison of self-drilling and self-tapping anterior cervical screws. European Spine Journal, 21( 5), 956-963. doi:10.1007/s00586-011-2120-z
    • NLM

      Porto MA, Silva P, Rosa R, Volpon JB, Shimano AC, Paula FJA de, Defino HLA. Experimental in vivo acute and chronic biomechanical and histomorphometrical comparison of self-drilling and self-tapping anterior cervical screws [Internet]. European Spine Journal. 2012 ; 21( 5): 956-963.Available from: http://dx.doi.org/10.1007/s00586-011-2120-z
    • Vancouver

      Porto MA, Silva P, Rosa R, Volpon JB, Shimano AC, Paula FJA de, Defino HLA. Experimental in vivo acute and chronic biomechanical and histomorphometrical comparison of self-drilling and self-tapping anterior cervical screws [Internet]. European Spine Journal. 2012 ; 21( 5): 956-963.Available from: http://dx.doi.org/10.1007/s00586-011-2120-z

    Referências citadas na obra
    Aebi M, Zuber K, Marchesi D (1991) Treatment of cervical spine injuries with anterior plating. Indications, techniques, and results. Spine (Phila Pa 1976) 16:S38–S45
    Champy M, Lodde JP, Schmitt R et al (1978) Mandibular osteosynthesis by miniature screwed plates via a buccal approach. J Maxillofac Surg 6:14–21
    Chapman JR, Harrington RM, Lee KM et al (1996) Factors affecting the pullout strength of cancellous bone screws. J Biomech Eng 118:391–398
    Chavassieux P, Pastoureau P, Boivin G et al (1991) Dose effects on ewe bone remodeling of short-term sodium fluoride administration—a histomorphometric and biochemical study. Bone 12:421–427
    Conrad BP, Cordista AG, Horodyski M et al (2005) Biomechanical evaluation of the pullout strength of cervical screws. J Spinal Disord Tech 18:506–510
    den Boer FC, Patka P, Bakker FC et al (1999) New segmental long bone defect model in sheep: quantitative analysis of healing with dual energy X-ray absorptiometry. J Orthop Res 17:654–660
    Ellis JA Jr, Laskin DM (1994) Analysis of seating and fracturing torque of bicortical screws. J Oral Maxillofac Surg 52:483–486
    Grubb MR, Currier BL, Shih JS et al (1998) Biomechanical evaluation of anterior cervical spine stabilization. Spine (Phila Pa 1976) 23:886–892
    Guntermann J, Gellrich NC, Schramm A et al (1998) The Synthes 1.5 and 2.0 self-drilling screws indication in maxillofacial surgery. J Craniomaxillofac Surg 26:65
    Hadjipavlou AG, Nicodemus CL, al-Hamdan FA et al (1997) Correlation of bone equivalent mineral density to pull-out resistance of triangulated pedicle screw construct. J Spinal Disord 10:12–19
    Heidemann W, Gerlach KL (1999) Clinical applications of drill free screws in maxillofacial surgery. J Craniomaxillofac Surg 27:252–255
    Heidemann W, Gerlach KL, Grobel KH et al (1998) Drill Free Screws: a new form of osteosynthesis screw. J Craniomaxillofac Surg 26:163–168
    Heidemann W, Terheyden H, Gerlach KL (2001) Analysis of the osseous/metal interface of drill free screws and self-tapping screws. J Craniomaxillofac Surg 29:69–74
    Heidemann W, Terheyden H, Gerlach KL (2001) In vivo studies of screw-bone contact of drill-free screws and conventional self-tapping screws. Mund Kiefer Gesichtschir 5:17–21
    Hitchon PW, Brenton MD, Coppes JK et al (2003) Factors affecting the pullout strength of self-drilling and self-tapping anterior cervical screws. Spine (Phila Pa 1976) 28:9–13
    Johnston TL, Karaikovic EE, Lautenschlager EP et al (2006) Cervical pedicle screws vs. lateral mass screws: uniplanar fatigue analysis and residual pullout strengths. Spine J 6:667–672
    Kaiser MG, Haid RW Jr, Subach BR et al (2002) Anterior cervical plating enhances arthrodesis after discectomy and fusion with cortical allograft. Neurosurgery 50:229–236
    Liebschner MA (2004) Biomechanical considerations of animal models used in tissue engineering of bone. Biomaterials 25:1697–1714
    Lohr J, Gellrich NC, Buscher P et al (2000) Comparative in vitro studies of self-boring and self-tapping screws. Histomorphological and physical-technical studies of bone layers]. Mund Kiefer Gesichtschir 4:159–163
    Mischkowski RA, Kneuertz P, Florvaag B et al (2008) Biomechanical comparison of four different miniscrew types for skeletal anchorage in the mandibulo-maxillary area. Int J Oral Maxillofac Surg 37:948–954
    Newman E, Turner AS, Wark JD (1995) The potential of sheep for the study of osteopenia: current status and comparison with other animal models. Bone 16:277S–284S
    Ogon M, Haid C, Krismer M et al (1996) Comparison between single-screw and triangulated, double-screw fixation in anterior spine surgery. A biomechanical test. Spine (Phila Pa 1976) 21:2728–2734
    Oktenoglu BT, Ferrara LA, Andalkar N et al (2001) Effects of hole preparation on screw pullout resistance and insertional torque: a biomechanical study. J Neurosurg 94:91–96
    Omeis I, DeMattia JA, Hillard VH et al (2004) History of instrumentation for stabilization of the subaxial cervical spine. Neurosurg Focus 16:E10
    Pastoureau P, Arlot M, Caulin F, Barlet J, Meunier P, Delmas P (1989) Effects of oophorectomy on biochemical and histological indices of bone turnover in ewes. J Bone Miner Res 4:S237, abstract 477
    Pearce AI, Richards RG, Milz S et al (2007) Animal models for implant biomaterial research in bone: a review. Eur Cell Mater 13:1–10
    Pitzen T, Barbier D, Tintinger F et al (2002) Screw fixation to the posterior cortical shell does not influence peak torque and pullout in anterior cervical plating. Eur Spine J 11:494–499
    Rodriguez-Olaverri JC, Hasharoni A, DeWal H et al (2005) The effect of end screw orientation on the stability of anterior instrumentation in cyclic lateral bending. Spine J 5:554–557
    Ronderos JF, Jacobowitz R, Sonntag VK et al (1997) Comparative pull-out strength of tapped and untapped pilot holes for bicortical anterior cervical screws. Spine (Phila Pa 1976) 22:167–170
    Ruland CM, McAfee PC, Warden KE et al (1991) Triangulation of pedicular instrumentation. A biomechanical analysis. Spine (Phila Pa 1976) 16:S270–S276
    Ryken TC, Clausen JD, Traynelis VC et al (1995) Biomechanical analysis of bone mineral density, insertion technique, screw torque, and holding strength of anterior cervical plate screws. J Neurosurg 83:325–329
    Ryken TC, Goel VK, Clausen JD, Traynelis VC (1995) Assessment of unicortical and bicortical fixation in a quasistatic cadaveric model. Role of bone mineral density and screw torque. Spine (Phila Pa 1976) 20:1861–1867
    Schatzker J, Sanderson R, Murnaghan JP (1975) The holding power of orthopedic screws in vivo. Clin Orthop Relat Res 108:115–126
    Schimming R, Gutwald R, Gellrich N et al (1999) Selfdrilling screws: clinical experiences in cranio- and maxillofacial surgery. Int J Oral Maxillofac Surg 28:26
    Scholz M, Reyes PM, Schleicher P et al (2009) A new stand-alone cervical anterior interbody fusion device: biomechanical comparison with established anterior cervical fixation devices. Spine (Phila Pa 1976) 34:156–160
    Sowden D, Schmitz JP (2002) AO self-drilling and self-tapping screws in rat calvarial bone: an ultrastructural study of the implant interface. J Oral Maxillofac Surg 60:294–299
    Su YY, Wilmes B, Honscheid R, Drescher D (2009) Comparison of self-tapping and self-drilling orthodontic mini-implants: an animal study of insertion torque and displacement under lateral loading. Int J Oral Maxillofac Implants 24:404–411
    Wu X, Deng F, Wang Z et al (2008) Biomechanical and histomorphometric analyses of the osseointegration of microscrews with different surgical techniques in beagle dogs. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 106:644–650