Facial measurements: reliability and correlation between two instruments (2017)
- Authors:
- USP affiliated authors: FUKUSHIRO, ANA PAULA - FOB ; YAMASHITA, RENATA PACIELLO - HRAC
- Unidades: FOB; HRAC
- Subjects: ANÁLISE FACIAL; PRÁTICA CLÍNICA; MEDIDAS
- Language: Inglês
- Abstract: Objective: To examine the correlation between two instruments of measurement used forfacial analyses, and to verify the reliability of their use in clinical practice. Methods: Facialmeasurements including inferior third(IT), width(WD), out corner of the eyes(CE), height ofupper(HU) and lower(HL) lips of 51 patients with cleft palate(CP), both genders, aged 19 to37(24.4±4.6) years were carried out by using a caliper. The same measurements wereperformed through the analyses of volumetric 3D reconstructions of cone beam computedtomography images of each patient by using Amira Software5.6. Reliability was calculatedafter reanalyzes of 100% of the images by using Interclass Correlation Coefficient(ICC).Correlation between the measurements resulted for both instruments was determined byPearson product-moment correlation. Differences between the methods of analysis wereobtained by one-sample t-test(95%). Results: The ICC obtained for IT, WD, CE, HU, and HLranged from .939 to.986(excellent reliability). The means of IT, WD, CE, HU, and HL were69.99(±11.90)mm, 109.21(±7.17.05)mm, 68.81(±8.48)mm, 19.40(±3.91)mm, and50.42(±8.73)mm for measures obtained using the caliper; and 65.35(±7.56)mm,104.07(±6.00)mm, 67.28(±5.27)mm, 18.29(±3.28)mm, and 46.03(±5.84)mm for measuresobtained using the software. Correlation between the measurements resulted from bothinstruments was strong for IT(r=0.91) and CE(r=0.85), moderate for HU(r=0.72) andHL(r=0.70), and weak for WD(r=0.44), p<0.001. Conclusion: In general, an acceptablecorrelation between the resulted measurements from both instruments was found. However,it has to be considered the application of strategies to reduce the possible errors of using acaliper during the evaluation process, thus, increasing the reliability and reproducibility ofthe assessments.
- Imprenta:
- Publisher: Hospital de Reabilitação de Anomalias Craniofaciais, Universidade de São Paulo
- Publisher place: Bauru
- Date published: 2017
- Source:
- Título do periódico: Anais
- Conference titles: Simpósio Internacional de Fissuras Orofaciais e Anomalias Relacionadas
-
ABNT
MEDEIROS, Maria Natália Leite de et al. Facial measurements: reliability and correlation between two instruments. 2017, Anais.. Bauru: Hospital de Reabilitação de Anomalias Craniofaciais, Universidade de São Paulo, 2017. Disponível em: https://repositorio.usp.br/directbitstream/ee4e6336-2843-4e96-97e3-5a2159775349/2940048.pdf. Acesso em: 19 abr. 2024. -
APA
Medeiros, M. N. L. de, Favaretto, F. S. R., Perry, J. L., Fukushiro, A. P., & Yamashita, R. P. (2017). Facial measurements: reliability and correlation between two instruments. In Anais. Bauru: Hospital de Reabilitação de Anomalias Craniofaciais, Universidade de São Paulo. Recuperado de https://repositorio.usp.br/directbitstream/ee4e6336-2843-4e96-97e3-5a2159775349/2940048.pdf -
NLM
Medeiros MNL de, Favaretto FSR, Perry JL, Fukushiro AP, Yamashita RP. Facial measurements: reliability and correlation between two instruments [Internet]. Anais. 2017 ;[citado 2024 abr. 19 ] Available from: https://repositorio.usp.br/directbitstream/ee4e6336-2843-4e96-97e3-5a2159775349/2940048.pdf -
Vancouver
Medeiros MNL de, Favaretto FSR, Perry JL, Fukushiro AP, Yamashita RP. Facial measurements: reliability and correlation between two instruments [Internet]. Anais. 2017 ;[citado 2024 abr. 19 ] Available from: https://repositorio.usp.br/directbitstream/ee4e6336-2843-4e96-97e3-5a2159775349/2940048.pdf - Resistência laríngea em indivíduos com fechamento velofaríngeo marginal
- Speech outcomes of surgical management of velopharyngeal insufficiency in subjects submitted to orthognathic surgery
- Classificação da hipernasalidade: influência do treinamento dos avaliadores
- Tratamento da insuficiência velofaríngea por meio do retalho faríngeo após a veloplastia intravelar: resultados de fala e respiração
- Efeito da cirurgia de veloplastia intravelar sobre o fechamento velofaríngeo avaliado por meio da técnica fluxo-pressão
- O uso da classificação global perceptivo-auditiva da competência velofaríngea e a nasalância: correlação com o background linguístico do ouvintes
- Influência das consoantes de alta e baixa pressão intraoral sobre a nasalidade e nasalância da fala
- Efeito da cirurgia do retalho faríngeo realizada após a veloplastia intravelar sobre a nasalidade de fala
- Sintomas de fala passivos e ativos após palatoplastia primária: comparação entre os tipos de fissuras labiopalatinas
- Correlação entre a área do orifício velofaríngeo e as características perceptivas da disfunção velofaríngea
Download do texto completo
Tipo | Nome | Link | |
---|---|---|---|
2940048.pdf | Direct link |
How to cite
A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas