Iterative method to achieve noise variance stabilization in single raw digital breast tomosynthesis (2021)
- Authors:
- USP affiliated authors: VIEIRA, MARCELO ANDRADE DA COSTA - EESC ; BRANDÃO, RENANN DE FARIA - EESC
- Unidade: EESC
- DOI: 10.1117/12.2580965
- Subjects: MAMOGRAFIA; PROCESSAMENTO DE IMAGENS; IMAGEM DIGITAL
- Agências de fomento:
- Language: Inglês
- Imprenta:
- Publisher place: Washington, DC
- Date published: 2021
- Source:
- Título do periódico: Proceedings of the SPIE : Physics of Medical Imaging
- ISSN: 1605-7422
- Volume/Número/Paginação/Ano: v. 11595
- Conference titles: SPIE Medical Imaging
- Este periódico é de assinatura
- Este artigo NÃO é de acesso aberto
- Cor do Acesso Aberto: closed
-
ABNT
BRANDÃO, Renann F. et al. Iterative method to achieve noise variance stabilization in single raw digital breast tomosynthesis. Proceedings of the SPIE : Physics of Medical Imaging. Washington, DC: Escola de Engenharia de São Carlos, Universidade de São Paulo. Disponível em: http://dx.doi.org/10.1117/12.2580965. Acesso em: 29 maio 2024. , 2021 -
APA
Brandão, R. F., Borges, L. R., Barufaldi, B., Vent, T. L., Caron, R. F., Oliveira, B. B., et al. (2021). Iterative method to achieve noise variance stabilization in single raw digital breast tomosynthesis. Proceedings of the SPIE : Physics of Medical Imaging. Washington, DC: Escola de Engenharia de São Carlos, Universidade de São Paulo. doi:10.1117/12.2580965 -
NLM
Brandão RF, Borges LR, Barufaldi B, Vent TL, Caron RF, Oliveira BB, Maidment ADA, Vieira MA da C. Iterative method to achieve noise variance stabilization in single raw digital breast tomosynthesis [Internet]. Proceedings of the SPIE : Physics of Medical Imaging. 2021 ; 11595[citado 2024 maio 29 ] Available from: http://dx.doi.org/10.1117/12.2580965 -
Vancouver
Brandão RF, Borges LR, Barufaldi B, Vent TL, Caron RF, Oliveira BB, Maidment ADA, Vieira MA da C. Iterative method to achieve noise variance stabilization in single raw digital breast tomosynthesis [Internet]. Proceedings of the SPIE : Physics of Medical Imaging. 2021 ; 11595[citado 2024 maio 29 ] Available from: http://dx.doi.org/10.1117/12.2580965 - Evaluating the simulation of radiation dose reduction in a digital breast tomosynthesis system featuring an amorphous silicon (a-Si) detector
- Evaluating the simulation of radiation dose reduction in a digital breast tomosynthesis system featuring an amorphous silicon (a-Si) detector
- Investigating the use of block-matching 3D denoising algorithm to reduce radiation dose in digital mammography
- Non-uniform illumination correction in non-mydriatic digital fundus camera
- Use of wavelet multiresolution analysis to reduce radiation dose in digital mammography
- Restored low-dose digital breast tomosynthesis: a perception study
- Restoration of low-dose digital breast tomosynthesis
- Mapeamento, classificação e dimensionamento de áreas geográficas por sensoriamento remoto utilizando processamento de imagens
- Sistema computadorizado para alinhamento automático e aferição do ponto focal de equipamentos mamográficos utilizando sensor CCD odontológico
- Uso do algoritmo de médias não-locais para filtragem do ruído de mamogramas adquiridos com dose reduzida
Informações sobre o DOI: 10.1117/12.2580965 (Fonte: oaDOI API)
Download do texto completo
Tipo | Nome | Link | |
---|---|---|---|
sysno3190274_trabalho 01.... |
How to cite
A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas